GCS Low voltage withdrawable switchgear
GCS low-voltage withdrawable switchgear is suitable for distribution systems in industries such as power plants, petroleum, chemical, metallurgical, textile, and high-rise buildings. In places with high automation requirements and computer interfaces such as large power plants, petrochemical systems, etc., as a low-voltage complete distribution device used for power distribution, centralized control of electric motors, and reactive power compensation in power generation and supply systems with a three-phase AC frequency of 50 (60) Hz, rated operating voltage of 380V (400V), (660V), and rated current of 4000A or less.
DFW Cable branch box with switch
Prefabricated live touchable silicone rubber cable heads, fully sealed, fully insulated, maintenance free, and reliable to ensure personal safety;
GZDW DC power cabinets are used in large, medium, and small power plants and substations as high-voltage switches for normal operation and emergency situations, relay protection, automatic control, and emergency lighting. The DC power supply required for lighting and audio signals can also be applied to industries such as metallurgy, railway, mining, petrochemicals, postal and telecommunications, communication, healthcare, banking, hotels, high-rise buildings, and computer networks. Microcomputer controlled DC power cabinets can be used for unmanned, remote centralized monitoring power plants, substations, and other industries.
GJ Low voltage intelligent reactive power compensation cabinet
GJ low-voltage intelligent reactive power compensation cabinet, is specially designed for the actual situation of the power grid. It adopts intelligent control technology, which effectively solves the problem of automatic switching of parallel capacitors for reactive power compensation under harmonic conditions. On the other hand, it can filter out harmonics according to users' actual requirements, clean the power grid environment, reduce losses, and eliminate harmonic hazards; And provide capacitive reactive power to the system to improve power factor. Can be used in power distribution systems for industries such as electricity, metallurgy, petrochemicals, industrial and mining enterprises, construction, and machinery.
GTDXF囗-12 AC metal solid insulated ring main switchgear
AC metal solid insulated ring main switchgear is a fully insulated, fully sealed, and maintenance free solid insulated vacuum switchgear. All high-voltage live parts are cast with epoxy resin material with excellent insulation performance, organically combining the vacuum arc extinguishing chamber, main electrical circuit, insulation support, etc. into a whole, and the functional units are connected through fully insulated solid busbar. Therefore, the entire switchgear is not affected by the external environment, ensuring the reliability of equipment operation and the safety of operators. This ring main unit has the characteristics of simple structure, flexible operation, reliable interlocking, and easy installation. It is suitable for 50Hz, 12 kV power systems and widely used in industrial and civil cable ring networks and distribution network terminal projects. It is used for the reception and distribution of electrical energy, especially for urban residential distribution, small substations, switch stations, cable branch boxes, box type substations, industrial and mining enterprises, shopping malls, airports, subways, wind power generation, hospitals, sports stadiums, railways, tunnels and other places. Due to its advantages of full insulation, full sealing, and full shielding, this product is particularly suitable for use in harsh environments such as high altitude, high temperature, humid heat, severe cold, and serious pollution.
New energy integrated prefabricated substation
Seo Tags:
Box-Type Substation Series
Category:
- Product Description
-
New energy integrated prefabricated substation, European style integrated machine. The European integrated machine includes oil diffusion transformer, high-voltage chamber, communication power cabinet, inverter room, and high-voltage room. The inverter room is placed on both sides of the transformer, and the communication power cabinet is placed next to the high-voltage chamber. The whole structure is in the shape of a grid, using a container as the fireproof insulation shell of the inverter room. The inverters in the inverter room are arranged in a mirror image, and there are side outlets for the inverters at the bottom of the wellhead between the inverter aisles. They are connected to the low-voltage bushing on one side of the transformer through copper bars and flexible connections. Heat sinks and transformer instrument boxes are installed on both sides of the transformer. The transformer adopts an oil immersed load switch with an inserted fuse core. The high-voltage fuse box, high-voltage bushing, and lightning arrester of the transformer are located in the high-voltage chamber, and the high-voltage bushing and cable are isolated from the fuse through the partition. The remote control monitoring room of the communication power cabinet is equipped with remote monitoring terminal equipment, auxiliary transformers, UPS, monitoring terminals and other devices. The secondary wires inside the power cabinet are laid through conduit between the high and low voltage rooms and connected to the inverter room. The transformer's heat dissipation method is natural air cooling (ONAN).
Working conditions
- Altitude: ≤ 3000 meters.
- Environmental temperature: -45 ℃~+45 ℃.
- Environmental humidity: The daily average relative humidity should not exceed 60%, and the monthly average should not exceed 90%.
- Installation location: A place without fire, explosion hazard, chemical corrosion, and severe vibration.
Technical specifications
No.
Items
Unit
High voltage apparatus
Transformer
Low voltage apparatus
1
Rated voltage
kV
6/10
6/0.4 10/0.4
0.4
2
Rated Capacity
kVA
50 and above
3
Rated Current
A
200、400、630
100~3200
4
Rated short circuit
breaking currentA
Load switch 400-600
15~63kA
kA
Depends on the fuse if it's combination switch
5
Rated short-time
withstand currentkA
16,20(4s)
15(1s)
30(1s)
6
Rated peak
withstand currentkA
31.5,50
30
63
7
Power frequency
withstand voltage
(1min)kV
Relatively and alternately 32/42
25/35(oil)
≤0.3,2
Isolating fracture 36/48
20/28(dry)
>0.3,2.5
8
Lightning impulse
withstand voltage
(peak value)kV
Relatively and alternately 60/75
60/75
Isolating fracture 70/85
9
Box protection level
IP44 IK10
10
Noise level
dB
45
11
Executive standard
GT/T 17467
DL/T 537